ECTIP Global B2B Sourcing & Market Entry Platform
Global Buyer RFQ

Purchase Requirement for 55,000 psi (3,792 bar) High-Pressure Washer – Panama

55000 Psi 3972 Bar Pressure Washer Type: Triplex, positive displacement, ceramic pistons. Pressure: 3, 792 bar (55, 000 psi). Minimum total flow: 5.5 GPM. Minimum speed: 1, 800 rpm. Coupled motor: Electric TEFC (Totally Enclosed Fan-Cooled), 200 HP (149 kW), continuous operation, no emissions, no combustion, no fuel maintenance or equivalent. Pressure control: External valve type ECV (Electric Control Valve). Cooling: Closed-loop liquid circuit. Lance flow: Capacity to adjust the flow according to the number of lances in operation and the size of nozzles used, delivering a constant pressure of 3, 792.0 bar (55, 000 psi) and a minimum flow of 5.5 gpm at a minimum operating speed of 1, 800 rpm. Water filtration and booster pump: To ensure water quality and constant pressure through water purification with 10-micron particle matter + booster pump. Minimum indicator lights for automatic shutdown in case of: Low water inlet pressure. High pump temperature. Low oil pressure in the pump. Operator control system. Intuitive interface with ISO symbols and multilingual display. If the equipment includes a water storage tank, it must be made of corrosion-resistant material, with a capacity of 150 to 190 liters. The tank can be external to the skid. Lubrication: Closed-loop oil circuit. Mounting: On skid-type structure, as well as the water treatment system, allowing easy transport with a forklift.

Buyer MarketPanama
CategoryIndustrial Parts
SubcategoryFasteners
Quantity190 Liter
Deadline2026-08-31T15:59:59.000Z
Statusquoting

Sourcing Requirements

55000 Psi 3972 Bar Pressure Washer Type: Triplex, positive displacement, ceramic pistons. Pressure: 3, 792 bar (55, 000 psi). Minimum total flow: 5.5 GPM. Minimum speed: 1, 800 rpm. Coupled motor: Electric TEFC (Totally Enclosed Fan-Cooled), 200 HP (149 kW), continuous operation, no emissions, no combustion, no fuel maintenance or equivalent. Pressure control: External valve type ECV (Electric Control Valve). Cooling: Closed-loop liquid circuit. Lance flow: Capacity to adjust the flow according to the number of lances in operation and the size of nozzles used, delivering a constant pressure of 3, 792.0 bar (55, 000 psi) and a minimum flow of 5.5 gpm at a minimum operating speed of 1, 800 rpm. Water filtration and booster pump: To ensure water quality and constant pressure through water purification with 10-micron particle matter + booster pump. Minimum indicator lights for automatic shutdown in case of: Low water inlet pressure. High pump temperature. Low oil pressure in the pump. Operator control system. Intuitive interface with ISO symbols and multilingual display. If the equipment includes a water storage tank, it must be made of corrosion-resistant material, with a capacity of 150 to 190 liters. The tank can be external to the skid. Lubrication: Closed-loop oil circuit. Mounting: On skid-type structure, as well as the water treatment system, allowing easy transport with a forklift.

Explore Global RFQs